The aircraft DC generator test system primarily consists of a main control cabinet, power unit, DC load bank, test cables, aviation DC generator, and DC generator regulator. It is mainly used to perform performance testing and operational compatibility checks for components such as the ZF-1.5 DC generator and TY-1500 voltage regulator.

Main features

  • The ZF1.5 generator offers two power ratings based on the cooling method: it delivers an output of 500 watts under natural ventilation and increases to 1000 watts with forced ventilation.
  • During operation, the generator ensures stable voltage, smooth parallel running, and is equipped with functions to prevent reverse current, resist overload, and reduce radio interference.
  • The generator features a four-pole shunt-wound design and supports reversible rotation direction.
  • It offers flexible installation options, supporting horizontal, inclined, and vertical mounting positions.

Technical Specification 

Parameter Name Cooling Method
"forced air circulation" "Spontaneous ventilation"
Rated power (Watts) 1000 500
Rated voltage (Volts) 27.5 27.5
Rated current (Amps) 40 20
Speed range (Rpm) 3800-5900 3800-5900
Operative Condition Continuous Continuous
Allowable overload current (Amps) 50 24
Overload Duration (Minutes) 2 2
The excitation current at thermal state should not exceed (Amps) at 3800 RPM, 27.5 Volts, and rated current. 2.80 2.55
Required amount of unheated air for "forced ventilation" Not less than 30 liters per second under normal atmospheric pressure  
Maximum permissible temperature rise of the generator assembly

 

Commutator

 

Excitation Winding Armature Winding

75

 

 

55

 

75

120

 

 

105

 

120